LDL100 Conductive Conductivity Sensor Ifm Compact Sensor Design Prevents Failures And Unplanned Downtime

Ask Latest Price
Video Channel
Brand Name :IFM
Model Number :LDL100
Certification :3C
Place of Origin :GERMANY
MOQ :1
Price :694$/piece
Payment Terms :T/T
Supply Ability :1piece in stock
Delivery Time :3 day
Packaging Details :103 x 45 x 46mm
System :gold-plated contacts
Communication interface :IO-Link
Weight[g] :270.5
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
Product characteristics
Number of inputs and outputs Number of analog outputs: 1
Process connection G 1/2 external thread
Application
System gold-plated contacts
Media Conductive liquids
Note on media water
milk
CIP liquids
Cannot be used for See the operating instructions, chapter "Function and features".
Medium temperature [°C] -25...100; (< 1 h: 150)
Pressure rating [bar] 16
Vacuum resistance [mbar] -1000
Electrical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 60
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 2
Inputs / outputs
Number of inputs and outputs Number of analog outputs: 1
Outputs
Total number of outputs 1
Output signal analog signal; IO-Link
Output function analog output; scalable; selectable conductivity / temperature
Number of analog outputs 1
Analog current output [mA] 4...20
Max. load [Ω] 500
ifmefector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — LDL100-01 — 13.09.2019 —
LDL100
Conductive conductivity sensor
COND CONDUCTIVITY HYG G1/2
Measuring/setting range
Measuring range [µS/cm] 100...15000
Temperature measurement
Measuring range [°C] -25...150
Accuracy / deviations
Accuracy (in the measuring 10 % MW ± 25 µS/cm
range)
Conductivity measurement
Resolution [µS/cm] 1
Drift [%/K] 0,2 %/K MW ± 25 µS/cm
Repeatability 5 % MW ± 25 µS/cm
Long-term stability 1 % MW ± 25 µS/cm
Temperature measurement
Accuracy [K] 20...50 °C: < ± 0,5 K;
-25...150 °C: < ± 1,5 K
Repeatability [K] 2
Resolution [K] 0.1
Reaction times
Conductivity measurement
Response time [s] < 2; (T09; Damping = 0)
Temperature measurement
Response time [s] < 9; (T09)
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
IO-Link device ID 0x000399 / 921
Profiles Measuring Sensor, Identification and Diagnosis
SIO mode no
Required master port class A
Process data analogue 1
Min. process cycle time [ms] 5.6
Operating conditions
Ambient temperature [°C] -40...60
Storage temperature [°C] -40...85
Protection IP 68; IP 69K; (IP 68: 7 days / 3 m water depth / 0.3 bar)
Tests / approvals
EMC DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance DIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years] 172
ifmefector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — LDL100-01 — 13.09.2019 —
LDL100
Conductive conductivity sensor
COND CONDUCTIVITY HYG G1/2
Mechanical data
Weight [g] 270.5
Material stainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts) PEEK; stainless steel (1.4404 / 316L)
Process connection G 1/2 external thread
Remarks
Remarks MW = Measured value
Pack quantity 1 pcs.
Electrical connection